Services

CP Monitoring & Maintenance

  • Monitoring of CP System
  • PSP & TR Unit
  • Monitoring & Maintenance
  • CP Troubleshooting
  • CP System Optimizatioon

CP Survey

We undertake Pre Installation and Post Installation Surveys concerning Cathodic Protection Systems. Close Interval Potential Logging ON-OFF/CIPL Survey as Pipeline Health Survey Pearson Survey examine the Coating Condition of equipment
Direct Current Voltage Gradient (DCVG) used for Inspecting coating of buried pipelines
Current Attenuation Test (CAT) used to locate poor leaks and defects which drain out the current from systems.
CP Monitoring/Maintenance:

Test stations are provided at sufficient locations for current measurements which facilitate Cathodic Protection testing. We undertake scheduled monitoring of various components in CPS on daily, weekly, monthly, quarterly and yearly basis as required.

Equipment Inventory

  • Digital Multimeter
  • Digital Clamp on Ammeter
  • Reference Cell
  • DCVG Equipment
  • CAT Equipment
  • Thermit Welding Kit
  • Holiday Testing kit
  • Soil Resistivity Meter
  • Pin Brazing Instrument

PCP System

  • Pre Design Servey
  • ICCP system Design
  • commissioning& post
  • Commissioning Serveys

TCP System

  • Pre Design Servey
  • Cp Design
  • Supply & Installtion of TLP Anodes Etc.

Fire Fighting & Alarm stems

  • Fire Alarm System
  • Fire Detector Installation
  • Co2 flooding system
  • Maintenance of Fire Alarm system
  • HV/MV Spray Systems.
  • Firewater storage Tanks.
  • Hydrant Networks.
  • Gas & Flame detection system.
 

Pipeline Coating Works

  • Coating Repair
  • Coating Material Supply
  • Coating Conductance Testing

Cathodic Protection for Underground Bullet Tank

  • TCP/PCP For Bullet Tanks
  • Cp System Design
  • Anode Installation
  • JB Installation , Cable Laying
 

Pipeline Integrity Management

CPNW have proven track record of providing Integrated operation & maintenance services as a single point responsibility and we undertake projects on umbrella contract as well as on Annual Maintenance Contract (AMC) basis. This include mainline maintenance activities such as ROU, Washouts, Markers, Emergency response, Cathodic Protection Monitoring & Maintenance and Station maintenance activities such as Mechanical, Electrical, Instrumentation, Civil Maintenance and station up keeping etc.

cross country pipelines of different sizes. Our technicians undertakes safe digging practices to avoid damage to existing underground pipelines. Our Operation & Maintenance team also have experience in Maintenance of Steel Pipeline, attending major Emergency etc.

Solar powered cathodic protection systems

The Cathodic Protection Controller is designed for trouble free service in all environments and includes many special features which make it easy to operate and maintain in the field. Power consumption and heat generation are minimised in the CP since efficient solid state circuitry is used instead of ballast resistors typical of earlier cathodic protection units. The power circuit contains no moving parts to wear out or break down. Quality digital voltage and current meters provide output monitoring which facilitates field adjustment. This is easily performed by inserting a small screwdriver through the faceplate. Recalibration can be performed in minutes without special tools or meter equipment. Since corrosion protection systems normally operate in remote, unattended sites, they should be protected from the common effects that make them fail such as: lightning exposure, battery damage, and short – circuits. That’s why every Sollatek CP Unit includes lightning transient suppression, a low battery shutdown circuit and output overload protection. Our dual transient protection network will suppress electrical spikes and surges that normally damage field equipment. If the storage batteries become discharged due to cloudy days or photovoltaic system failure, the CP Unit will automatically shut down, preventing excessive discharge and protecting the battery from permanent damage and costly replacement. Our built-in circuit breaker prevents damage to the CP and other components, should the output leads become shorted to one another. To help reduce overall system cost, the CP includes adjustable current and voltage outputs. Standard photovoltaic modules can be used and the CP output adjusted to the desired level.

Scroll to Top